Teckentrup Fire-retardant aluminium door T30-FSA "SCHÜCO FIRESTOP ADS 90 FR 30"

Teckentrup GmbH & Co. KG

Description

1- or 2-leaf door Schüco FireStop ADS 90 FR 30, thermally separated aluminium system for fire protection closures T30. Tested door-wall program according to EN 1634/EN 1364 (DIN 4102). With 90 mm foundation depth and glazing arranged on one side. Fire-retardant glazing, F30. The components can be optionally designed in T-connector construction or combinable construction. The type is to be determined according to the structural conditions / requirements. The door leaves are to be designed with a 4-sided, mitre-made leaf / leaf base. Profile construction depths: frame, mullions, transoms, sash frame, plinth 90 mm. Surface frame / sash finished lacquered in accordance with RAL 9010.

Broschüre

More Over


Product features:

Tested door-wall range according to EN 1634/EN 1364 (DIN 4102)

of fire resistance class T30/F30:

  • T30-1-FSA (RS) "Schüco FireStop ADS 90 FR 30"
  • Approval letter No.: Z-6.20-2330
  • F30 Fire-retardant glazing:
  • Approval Letter No.: Z-19.14-2271

Installation in:
  • Masonry at least 115 mm
  • Concrete at least 100 mm
  • Lightweight stud wall at least 100 mm
  • Aerated concrete min. 150 mm
  • Clad steel and timber columns F30

Technical Information

Size range:

Outer frame dimensions 1-leaf

  • width: 605 – 1642 mm
  • Height: 1740 – 3171 mm

Frame outer dimensions 2-leaf

  • width: 1355 – 3164 mm
  • Height: 1740 – 3171 mm
Surface:
  • Final coated RAL of your choice or anodised shades
Construction:
  • 1- and 2-leaf doors in combination with side panels and skylights
  • Standard: T-connection
  • frame construction construction
  • depth 90 mm
  • Face width (frame frame) 71 mm
  • Face width (frame and sash) 145 mm
  • Face width plinth 96 mm
  • Total plinth height incl. 8 mm Floor clearance 104 mm
Special equipment:
  • Locking combination according to DIN 179 and DIN 1125
  • Glass variations (foils)
  • Fire protection panels
  • Handle / interchangeable sets made of light metal, stainless steel
  • Panic fittings in accordance with DIN EN 1125
  • Hinge variants Door
  • closers with smoke alarm system and hold-open
  • door
  • operators
  • Electric
  • door openers
  • Locking controls (bolt contact)
  • Opening detectors (reed contact)
  • Escape monitoring systems
  • Access controls

Downloads