The construction:
Widths of W = 100, 115, 150 and 175 mm are possible. By combining the widths, aerated concrete flat lintels can be used for all common wall thicknesses. The flat lintel B = 100 mm is only permissible in combination with another aerated concrete flat lintel B ≥ 100 mm as a load-bearing component. The joint width between the tension belts must not exceed 15 mm. The load-bearing capacity is achieved by a masonry at least 125 mm high with aerated concrete flat blocks of at least strength class PP2. Alternatively or in combination, a reinforced concrete component (e.g. ceiling) can also be used as a pressure zone. The bearing and butt joints must be completely mortared with thin-bed mortar so that a pressure vault can form.