More Over
Thermal
insulation for unused and used flat roofs. Permissible scope of application according to DIN 4108, Part 10: DAA (external insulation of roof and ceiling, protected from the weather). Processing in accordance with the technical rules for roofs with waterproofing.
Technical Information
AbZ-No. Z-23.15-1498
Thermal conductivity λ (W/(mK): 0.035 Design value according to AbZ
Quality type: EPS 035 i.e. 150 kPa
Building material class according to DIN 4102 B1
Firebehaviour EN 13501-1 Euroclass E
Compressive stress σ 10%: kPa/ kN/m² - > 150 according to DIN EN 826 = 15.0 t/m²
Compressive stress σ 2%: kPa/ kN/m² - > 45 according to DIN EN 13163 = 4.5 t/m²
CE code: EN 13163 EPS-EN 13163:12-T2-L3-W3-S5-P10-BS200-CS(10)
150-DS(N)5-DLT(2)5
Formats plate: 1000x1200 mm /1000x1000 mm /1000x500 mm /1200x500 /
1500x1200
Formats GLD (slope) 1000x1200 mm /1000x1000 mm /1000x500 mm
Thicknesses: from 20 mm
Slope: from 1 % in 0.5 % - steps upwards
Behaviour: Chemically and biologically neutral: HCFC and HFC-free
Lamination: On request
Packaging: bundled in packages or loosely stretched on one-way pallets Disposal: packaging film via Interseroh, membership number 221184
marking Slope: position number and water flow
direction Marking plate: roll stamp
Downloads