Rockwool Hardrock® 038

DEUTSCHE ROCKWOOL GmbH & Co. KG

Description

Pressure-resistant, highly thermally insulating rock wool roof insulation board with integrated two-layer characteristic in thermal conductivity 038. Particularly high-density, load-distributing top layer for improved resistance to mechanical stress.

More Over

Due to its particularly high-density, load-distributing top layer, it offers improved resistance to mechanical stress

  • Thermal insulation material for buildings
  • Factory-produced mineral wool (MW) in accordance with DIN EN 13162
  • Non-combustible
  • Melting point > 1000 °C
  • Non-smoldering
  • Heat and sound insulation
  • Pressure-resistant
  • Diffusion-open
  • Chemically neutral
  • dimensionally stable recyclable under temperature change
  • KEYMARK quality monitoring

Technical Information

  • Designation code according to DIN EN 13162: MW-EN 13162-T4-DS(70,90)-CS(10)70-TR10-PL(5)800-WS-MU1
  • Dimensional stability at defined temperatureDS(70,90) | fulfilled | DIN EN 1604
  • Main areas of application Unused flat roofs with increased requirements for thermal insulation; Examples: extensive green roofs, photovoltaics
  • DAA | Exterior insulation of roofs or ceilings, insulation under waterproofing | DIN 4108-10
  • Surface Marked by a lettering
  • Limit dimensions for thicknesses T | T4 | DIN EN 823
  • Smouldering behaviour no tendency to continuous smouldering | DIN EN 16733
  • Non-combustible reaction to fire, A1 | DIN EN 13501-1
  • Nominal value of thermal conductivity λD | 0.037 W/(m∙K) | DIN EN 13162
  • Design value of thermal conductivity λB | 0.038 W/(m∙K) | DIN 4108-4:2017-03
  • Temperature behaviour Melting point of rock wool > 1000° C, use for short periods approx. 250° C | DIN 4102-17
  • Short-term water absorption WS | fulfilled | DIN EN 1609
  • Water vapour diffusion resistance coefficient MU | μ = 1 | DIN EN 12086
  • Compressive stress at 10 % compression CS(10) | σ10 ≥ 70 kPa | DIN EN 826
  • Point Load at 5 mm Compression PL(5) |  FP ≥ 800 N | DIN EN 12430
  • Load on the roof moderately to strongly
  • tensile strength perpendicular to the plate plane TR | σmt ≥ 10 kPa | DIN EN 1607

Downloads