HUECK TRIGON UNIT L

HUECK System GmbH & Co. KG

Description

Thermally insulated aluminium façade construction in element construction for vertical, polygonal façade walls.

More Over

Construction

  • Thermally insulated aluminium façade construction in element construction for vertical, polygonal façade walls
  • Optimised profile geometry in terms of weight and static values
  • Glass thicknesses from 2 mm to 50 mm
  • Different insert elements from the HUECK system possible

Face width

  • Frame and post profiles with 33 mm, 50 mm and 75 mm face widths

Profile construction depth

  • Frame profile with 137 mm, post profiles from 50 mm to 137 mm depending on static requirements

Seals

  • Inner sealing profiles can be used either as vulcanised frames or by the metre
  • Regardless of the weather, without sealant on the construction site
Test

results

  • Uf ≥ 0.93 W/m²K
  • Driving rain tightness static: RE 1200 (BS-EN 12154 and CWCT section 6)
  • Dynamic driving rain tightness: 300 Pa / 900 Pa EN 13050
  • Air permeability class AE 900 EN 12152
  • Resistance to wind: 2400 Pa / 3600 Pa EN 12179
  • Impact resistance: I5/E5 (EN 14019)
  • Burglary resistance: RC2 (EN 1627)
  • Seismic resistance: according to (AAMA 501.4:2000)
  • Tests according to CWCT, ASTM and AAMA

Technical Information

The manufacturer has not yet provided any further information.