GUTEX Thermosafe®

GUTEX Holzfaserplattenwerk H. Henselmann GmbH & Co. KG

Description

The GUTEX Thermosafe® is a universal, multi-layer insulation board.

It is available in thicknesses of 40, 60, 80, 100 and 120 mm and is supplied in the 1200x625 mm format.


More Over

Areas of application:

  • On-roof insulation on full-surface substrate
  • Insulation of
  • the upper floor ceiling with medium compressive load capacity
  • Insulation of timber frame and timber panel construction
  • Insulation of solid wood walls and masonry (rear-ventilated façade)
  • Lightweight partition walls
  • according to DIN 4108-10: DAD-dm, DZ, WAB, WH, WTR

Advantages:

  • time-saving and easy installation due to high dimensional accuracy
  • multi-layer bulk density profile
  • optimal thermal insulation
  • excellent heat storage capacity, good summer heat and winter cold protection
  • improves sound insulation
  • diffusion-open and moisture-regulating
  • sustainable raw material wood
  • recyclable
  • building biologically harmless (natureplus© certified)
  • made in Germany (Black Forest)

Technical Information

Thickness: 40 mm

Format: 1200x600 mm

Edge formation: Stump

Dimensions & weight

Width (mm): 1200

Length (mm): 625

Covering dimension, length x width (mm): 1200 x 625

Square metres per panel (m2): 0.75

Weight per m2 (kg): 6.4

Weight per panel (kg): 6.4

Panels per pallet (pcs): 112

Square metres per pallet (m2): 84

Weight per pallet (kg): 570

Bulk density (kg/m3): 160

Insulation properties Thermal

conductivity Nominal value λD (W/mK): 0.038

Design value Thermal conductivity (W/mK): 0.040

Nominal thermal resistance RD (m2K/W): 1.05

Thermal resistance design value R (m2K/W): 1.00

Sd value (m): 0.20

Vapour diffusion (μ): 5

Specific heat capacity (J/kgK): 2100

Other characteristic values

compressive stress/strength (kPa) according to DIN EN 826: 50

Tensile strength perpendicular to the plate plane (kPa) according to DIN EN 1607

Short-term water absorption (kg/m2) according to DIN EN 1609

Dynamic stiffness (MN/m) according to DIN EN 29052-1: -

Compressibility (mm) according to DIN EN 13171: -

Flow resistance (kPas/m2) according to DIN EN 13171: 100

Reaction to fire: Euroclass according to DIN EN 13501-1: E

Downloads

Used in Projects