- Resistance to static load: rigid underlay -> ≥ 20 kg (Method A)
flexible underlay -> ≥ 20 kg (Method B) (DIN EN 12730)
- Resistance to impact load: rigid underlay -> ≥ 1000 mm kg (Method A)
flexible underlay -> ≥ 1250 mm (Method B) (DIN EN 12691)
- Resistance to root penetration: passed (DIN EN 13948)
- Tear resistance: longitudinal (Mr)* ≥ 9.0 N/mm²
transverse (QMr)* ≥ 7.0 N/mm² (DIN EN 12311-2)
- Elongation at break: longitudinal (Mr)* ≥ 550%
transverse (QMr)* ≥ 550% (DIN EN 12311-2)
- dimensional accuracy: longitudinal (Mr)* ≤ 0.2%
transverse (QMr)* ≤ 0.1 % (DIN EN 1107-2)
*Mr = machine direction *QMr = transverse to the machine direction
- Shear resistance of the joining seam: ≥ 500 N/50 mm (DIN EN 12317-2)
Tearing outside the joining seam (DIN SPEC 20000-201 / DIN EN 12317-2)
- Behaviour when folding at low temperatures: ≤ -45 °C (DIN EN 495-5)
- -Reaction to fire: Class E (EN ISO 11925-2) Classification according to DIN EN 13501-1
- Effect of liquid chemicals including water: on request: (DIN EN 1847)
- Behaviour under the influence of bitumen: passed (DIN EN 1548)
Method (b) (DIN SPEC 20000-201) (DIN EN 1548)
- UV exposure: passed (> 5,000 h) (DIN EN 1297)
Class 0 (DIN SPEC 20000-201) (DIN EN 1297)
- Water vapour permeability: μ= 150,000 (± 30%) (DIN EN 1931)