The RAVATHERM™ XPS 500 SL thermal insulation boards, made of closed-cell polystyrene foam, are the perfect solution for the thermal insulation of highly stressed inverted roofs, floor structures and load-bearing reinforced concrete slabs. Even in the long term, they offer a high load capacity, only low compression and excellent thermal insulation properties even in humid environments.
More Over
Excellent thermal insulation Waterproof
, moisture-resistant
Environmentally friendly
High compressive strength
Does not sink, does not shrink
Resistant
Areas of application:
Inverted roof
Drive-over inverted roofs
Foundation
Gravel inverted roofs
Technical Information
Density: DIN EN 1602 40 kg/m3
Compressive stress or compressive strength at 10% compression: CS(10\Y) DIN EN 826 500 kPa
Modulus of elasticity: DIN EN 826 < 50 mm 15,000 kPa
≥ 50 mm 25,000 kPa
Long-term creep behaviour (50 years) at 2% compression: CC(2/1.5/50)σ DIN EN 1606 180kPa
Calculation. Rated value of compressive stress fCD under foundation plates: all. Type approval Z-23.34-1324 50 – 120 mm 255 kPa
121 – 200 mm 230 kPa
multi-layer 230 kPa
Water absorption during long-term immersion: WL(T) DIN EN 12087 0.7%
Water absorption by diffusion: WD(V) DIN EN 12088 < 50 mm 3%
50 – 79 mm 2%
≥ 80 mm 1%
Water absorption after freeze-thaw alternating stress: FTCD DIN EN 12091 1%
Linear coefficient of thermal expansion: 0.07 mm/(m·K)
Dimensional stability under defined temperature (70°C) and humidity conditions 90%: DS(70/90) DIN EN 1604 <5%
Deformation under defined pressure (40kPa) and temperature (70°C): DLT(2)5 DIN EN 1605 <5%
Reaction to fire: DIN EN 13501-1 Euroclass E
Edge formation: Step rebate
Surface finish: Foaming skin
Areas of application: DIN 4108-10 DAA-ds, DUK-ds, DEO-ds, PW-ds, PB-ds