HUECK TRIGON 50 D

HUECK System GmbH & Co. KG

Description

The HUECK TRIGON 50 D is a thermally insulated aluminium façade construction in mullion-transom construction for sloping, vertical or flat façade walls with notches in the transom area.

Identical profile geometries for posts and transoms as well as different inserts are possible. The HUECK TRIGON 50 D can accommodate glass thicknesses from 20 mm to 58 mm.

More Over

Face width

Posts/transom and cover profiles with 50 mm face width in various profile geometries

Profile construction depth

Depending on static requirements from 32 mm to 204 mm

Insulation zone

Insulation profiles made of glass fibre reinforced plastic profiles

Foamed insulation profiles for increased thermal insulation

Seals

In the area of transom connections, vulcanized sealing molded parts are used, which cover the entire joint area

Optionally one-piece or two-piece EPDM seals can be used as external seals

on the construction site without sealant

Din Standard

  • DIN EN 949, Edition: 1999-05 Windows, doors, shutters, curtain walls - Determination of the resistance of doors to the impact of a soft and heavy impact body; German version EN 949:1998
  • DIN EN 1364-1, Edition: 2015-09 Fire resistance tests for non-structural components - Part 1: Walls; German version EN 1364-1:2015
  • DIN EN 1364-3, Edition: 2006-12 Fire resistance tests for non-load-bearing components - Part 3: Curtain walls - Overall design; German version EN 1364-3:2006 Document has been corrected
  • DIN EN 1364-3 Corrigendum 1, Edition: 2007-03 Fire resistance tests for non-load-bearing components - Part 3: Curtain walls - Overall design; German version EN 1364-3:2006, Corrigenda to DIN EN 1364-3:2006-12
  • DIN EN 1364-4, Edition: 2007-06 Fire resistance tests for non-load-bearing components - Part 4: Curtain walls - Partial execution; German version EN 1364-4:2007
  • DIN EN 1364-5, Edition: 2017-09 Fire resistance tests for non-load-bearing components - Part 5: Ventilation modules; German version EN 1364-5:2017
  • DIN EN 12152, Edition: 2002-08 Curtain walls - Air permeability - Performance requirements and classification; German version EN 12152:2002
  • DIN EN 12153, Edition: 2000-09 Curtain walls - Air permeability - Test methods; German version EN 12153:2000
  • DIN EN 12154, Edition: 2000-06 Curtain walls - Driving rain tightness - Performance requirements and classification; German version EN 12154:1999
  • DIN EN 12155, Edition: 2000-10 Curtain walls - Driving rain tightness - Laboratory test with application of static pressure; German version EN 12155:2000
  • DIN EN 12179, Edition: 2000-09 Curtain walls - Resistance to wind load - Test methods; German version EN 12179:2000
  • DIN EN 13050, Edition: 2011-09 Curtain walls - Driving rain tightness - Laboratory test with changing air pressure and spraying with water; German version prEN 13050:2006
  • DIN EN 13051, Edition: 2001-11 Curtain walls - Driving rain tightness - Field test; German version EN 13051:2001
  • DIN EN 13116, Edition: 2001-11 Curtain walls - Resistance to wind load - Performance requirements; German version EN 13116:2001
  • DIN EN 13119, Edition: 2007-07 Curtain walls - Terminology; Trilingual version EN 13119:2007
  • DIN EN 13830, Edition: 2015-07 Curtain walls - Product standard; German version EN 13830:2015
  • DIN EN 13947, Edition: 2007-07 Thermal behaviour of curtain walls - Calculation of the heat transfer coefficient; German version EN 13947:2006 Corrigendum document (predecessor document DIN EN 13947:2007-03
  • DIN EN 14019, Edition: 2004-09 Curtain walls - Impact resistance - Performance requirements; German version EN 14019:2004
  • DIN 18351, Edition: 2015-08 VOB Procurement and Contract Regulations for Construction Services - Part C: General Technical Contract Conditions for Construction Services (ATV) - Rear-ventilated facades
  • DIN 18516-1, Edition: 2010-06 Exterior wall cladding, rear-ventilated - Part 1: Requirements, Test Principles
  • DIN 18516-3, Edition: 2011-11 Exterior wall cladding, rear-ventilated - Part 3: Natural stone; Requirements, Design
  • DIN 18516-4, Edition: 1990-02 Exterior wall cladding, rear-ventilated; toughened safety glass; Requirements, Design, Testing
  • DIN 18516-5, Edition: 1999-12 Exterior wall cladding, rear-ventilated - Part 5: Cast stone; Requirements, design

Technical Information

  • Thermal insulation: Uf= 1.0 - 3.2 W/m²K
  • Driving rain tightness static RE 1200, dynamic 250 Pa / 750 Pa (EN 12154)
  • Air permeability class AE (EN 12152)
  • Resistance to wind 2.4 kN/m² permissible load or 3.6 kN/m² increased load (EN 12179)
  • Bullet resistance up to FB6-S
  • Burglary resistance WK 1 / WK2 / WK3
  • (ENV 1627)
  • Cross-series system components: fittings, accessories, additional profiles, aids, tools
  • Glass thicknesses from 20 to 58 mm
  • Drainage system based on the shingle principle
  • Ventilation moulded parts
  • Concealed openings in the pressure profiles of the mullions
  • Windows, doors and skylights in different types of openings
  • Impact resistance: I5 / E5 (EN 14019)