Rockwool Fixskirt 035

DEUTSCHE ROCKWOOL GmbH & Co. KG

Description

Non-combustible, dimensionally stable rock wool insulation board with thermal conductivity 035. Suitable for the insulation of rear-ventilated façades.

More Over

  • Thermal insulation material for buildings – factory-produced mineral wool (MW) in accordance with DIN EN 13162
  • Non-combustible
  • Melting point > 1000 °C
  • Non-smouldering
  • Heat and sound insulation
  • Continuously water-repellent
  • Diffusion-open
  • Quick and easy to install
  • Recyclable
  • KEYMARK Quality monitoring
  • non-combustible, A1

Thickness 100 to 200 mm: Fastening possible with only 1 dowel per panel (note see Fixrock single-dowel installation or data sheet). For single-dowel installation, consultation with the responsible sales representative or the central application technology department (Tel.: 02043 408 408) is required in advance.

This product is suitable in combination with the Fixrock BWM Fire Bolt Kit. Facade insulation board made of rock wool

☛ Tender texts at "www.aussschreiben.de"

Din Standard

  • DIN EN 822 (Standard), Edition: 2013-05 Thermal insulation products for the building industry - Determination of length and width; German version EN 822:2013
  • DIN EN 823 (Standard), Edition: 2013-05 Thermal insulation products for the building industry - Determination of thickness; German version EN 823:2013
  • DIN EN 824 (Standard), Edition: 2013-05 Thermal insulation products for the building industry - Determination of perpendicularity; German version EN 824:2013
  • DIN EN 825 (Standard), Edition: 2013-05 Thermal insulation materials for the building industry - Determination of flatness; German version EN 825:2013
  • DIN EN 826 (Standard), Edition: 2013-05 Thermal insulation materials for the building industry - Determination of behaviour under compressive stress; German version EN 826:2013
  • DIN EN 1602 (Standard), Edition: 2013-05 Thermal insulation products for the building industry - Determination of bulk density; German version EN 1602:2013
  • DIN EN 1603 (standard), edition: 2013-05 Thermal insulation materials for the building industry - Determination of dimensional stability in normal climate (23°C/ 50% relative humidity); German version EN 1603:2013
  • DIN EN 1604 (Standard), Edition: 2013-05 Thermal insulation materials for the building industry - Determination of dimensional stability under defined temperature and humidity conditions; German version EN 1604:2013
  • DIN EN 1605 (Standard), Edition: 2013-05 Thermal insulation materials for the building industry - Determination of deformation under defined pressure and temperature stress; German version EN 1605:2013
  • DIN EN 1606 (standard), Edition: 2013-05 Thermal insulation products for the building industry - Determination of long-term creep behaviour under compressive stress; German version EN 1606:2013
  • DIN EN 1607 (Standard), Edition: 2013-05 Thermal insulation materials for the building industry - Determination of tensile strength perpendicular to the plate plane; German version EN 1607:2013
  • DIN EN 1608 (Standard), Edition: 2013-05 Thermal insulation products for the building industry - Determination of tensile strength in panel plane; German version EN 1608:2013

Technical Information

  • Nominal thermal conductivity: λD | 0.034 W/(m∙K) | DIN EN 13162
  • Design value of thermal conductivity: λ | 0.035 W/(m∙K) | DIN 4108-4
  • Length-related flow resistance: AFr5 | ≥ 5 kPa · s/m² | DIN EN ISO 29053
  • Long-term water absorption: WL(P) | WL(P) | DIN EN 12087
  • Compressive stress at 10 % compression: CS(10) 0.5 | σ10 ≥ 0.5 kPa | DIN EN 826
  • Non-woven lamination: no non-woven lamination
  • Tensile strength perpendicular to the plate plane: TR 1 | σmt ≥ 1 kPa | DIN EN 1607